Industry / 5G, telecom and network equipment

5G and telecom die casting: IP rating, heat and EMI in one housing

An outdoor 5G telecom housing has to keep water out, get heat out and keep interference in, all through a gasket land that is machined after casting. Those three requirements pull the die design in different directions.

5G, telecom and network equipment component planning 5G, telecom and network equipment component planning
IP65–IP67
Sealing target on outdoor units
1.5–2 mm
Typical wall and fin root
0.05 mm
Gasket land flatness after machining
480–720 h
Salt spray target with coating
01 / What the part must do

Three 5G telecom requirements that meet on one machined face

A 5G outdoor unit is a sealed box holding electronics that generate heat. The die casting is the box, the heat sink and the electromagnetic shield at the same time. The design problem is that all three functions depend on the same surfaces, and each one wants something different from them.

Sealing wants a flat, uninterrupted gasket land with a groove that compresses the gasket evenly. Thermal design wants tall, thin fins on the outside and a flat, thick base under the heat source. Shielding wants a continuous conductive path across every joint, which means a groove for a conductive gasket and a coating that conducts.

The casting can deliver all three, but only if the machining and coating plan is decided before the die is cut. A gasket land that is not machined flat will not seal at IP66 no matter how good the gasket is, and an EMI groove that is cast to tolerance will not hold a conductive gasket at a consistent compression.

  • Outdoor pole-mount and roof-mount cabinets
  • Remote radio unit housings and covers
  • Indoor baseband and switch enclosures
  • Antenna and radio mounting brackets
  • Power and battery enclosures for site equipment
02 / Requirement map

What each requirement asks of the casting

The table is the DFM conversation in one page: each row is a customer requirement translated into a die, machining or coating decision.

RequirementWhat it decides in the partHow it is verified
IP65 / IP66 sealingMachined gasket land, groove section, screw pitch, no porosity in the landAir decay or water test on the assembled unit
IP67 immersionDeeper groove, higher screw density, sealed cable glands, flatter landImmersion test at the specified depth and time
EMI shieldingContinuous wall, gasket groove for a conductive gasket, conductive coatingBonding resistance and shielding effectiveness on the assembly
Thermal performanceFin height, fin thickness, base thickness, flat mounting padThermal test of the finished unit, or simulation plus a coupon
Salt spray lifeAlloy choice, conversion coating, powder coat, stainless fastenersSalt spray on coated coupons and parts
Weight and wind loadWall thickness distribution, rib layout, mounting boss designStatic and vibration test of the assembly
IP ratings are certified on the assembled product by a test house, not on a bare casting. The casting and the machining plan are what make the rating achievable; the test is what proves it.
03 / Sealing

Designing the gasket land

Machine the land, do not cast it

A die casting as-cast surface carries draft, parting-line witness and a skin that is not flat enough for a compressed gasket. The land is machined, typically 0.3–0.5 mm off, to 0.05 mm flatness and Ra 1.6 or better.

The groove is machined at the same setup as the land, so the gasket sits at a consistent depth relative to the sealing surface. Casting the groove and machining only the land is the mistake that produces leaks at one corner.

Screw pitch and land width

Gasket compression between screws follows a curve, not a straight line. On a 4 mm gasket, screw pitch of 60–80 mm keeps compression within the gasket's usable range; wider pitch lets the land bow between fasteners and the seal opens at the midpoint.

Land width is set by the gasket section plus a margin: a 3 mm gasket on a 6 mm land gives 1.5 mm either side, which is enough to survive assembly tolerance without the gasket rolling out of the groove.

Porosity where it matters

A gas pore that connects the inside of the housing to the gasket land is a leak path regardless of the gasket. The die is gated so the land is fed last into an overflow, and porosity acceptance is written for the land band specifically, not for the whole part.

Where a leak path survives, vacuum impregnation is a standard remedy and is specified as a process, with a re-test after impregnation.

04 / Thermal and EMI

Fins, flat pads and a conductive path

Fin geometry that casts and works

Typical outdoor telecom fins are 1.5–2.5 mm thick at the root, 8–15 mm tall, with 4–6 mm gaps. Thinner fins transfer heat better per unit mass but fill poorly and wear the die; the practical floor on a production die is around 1.2 mm at the tip for a tall fin.

Fins run vertically in service so air can move between them. A fin pattern that looks good on the drawing but runs horizontally in the installed orientation is a thermal design that only works in the lab.

The mounting pad is a machined face

The heat source sits on a pad that must be flat enough for a thermal interface material to work: 0.05 mm over the pad, Ra 1.6 or better, and no porosity under the pad. That pad is machined after casting and checked on a CMM.

Base thickness under the pad is a thermal decision and a casting decision at once. Too thin and the pad deflects under clamping; too thick and the heat path lengthens. 4–6 mm is the usual working range for this class of housing.

EMI: continuity, not just a coating

Shielding works when the joint between cover and body is electrically continuous. That means a machined or coined mating face, a gasket groove sized for a conductive gasket, and a coating that actually conducts: zinc arc spray, nickel-filled paint or a conductive conversion coating.

Bonding resistance is measured across the assembled joint, typically under 10 mΩ. Powder coat alone is an insulator and will fail that measurement, which is why the coating plan and the masking plan are one decision.

05 / Corrosion and assembly

Outdoor life and the parts that are not die cast

Alloy and coating for a coastal site

ADC12 or A380 with a conversion coating plus powder coat is the standard outdoor system; A360 is chosen where the coating is thin or the environment is aggressive, because the alloy itself resists corrosion better.

Salt spray targets of 480 h and 720 h are common. They are met by the coating system, and the coating system only works if the casting surface is sound: a blister over a gas pore is a coating failure that started in the die.

Galvanic isolation and drainage

Stainless fasteners into an aluminum housing are a galvanic couple. Insulating washers, a sealed fastener or a sacrificial coating at the interface is the standard fix.

Every outdoor housing needs a drain or a breather: a sealed box that breathes through its gasket pulls water in as it cools. A Gore-type breather vent in a machined port is part of the design, not an accessory.

Assembly features

Cast bosses for threaded inserts, machined gland ports, hinge and latch features, and a mounting interface that matches the pole bracket are all part of the same casting. Each one is a machining operation, and the fixture plan decides how many setups the part needs.

A housing that needs three setups costs more than one that needs two, even when the casting price is the same.

06 / Inspection

What is checked on a telecom housing

CharacteristicMethodFrequency
Gasket land flatnessCMM or surface plate with a dial indicatorFirst article, then per lot
Groove depth and widthCMM or gaugeEvery lot
Porosity in the land and under the padX-ray and sectioningFirst article and periodic
Leak tightness, assembledAir decay or water immersion100% where specified
Fin geometrySectioning or optical check on a couponFirst article
Coating thickness and adhesionCoating certificate, cross-hatchPer coating lot
Bonding resistance of the EMI jointMilliohm meter on the assemblyFirst article and sample
The gasket land and the machined pad are the two features that decide whether the unit passes its environmental tests. Both are machined features, and both belong on the CMM program.
07 / Typical parts

Three parts this page is written for

An outdoor remote radio housing is the full problem in one part: gasket land machined on two faces, fins on the back, an EMI groove for the cover, and a mounting interface that takes the wind load.

A pole-mount equipment cabinet is the same problem at a larger size, with the added constraint of a hinged door and a cable entry that must stay sealed through installation and service.

A shielded cover or chassis plate is the smaller case: the casting carries the gasket groove and the conductive path, and the thermal job belongs to a separate heat sink.

Buyer questions

Telecom housing questions that change the quotation

Sealing, shielding, thermal and outdoor life are the four answers that decide whether a die casting is the right process at all.

Yes, and IP67 with a deeper groove and higher screw density, but the rating is achieved by the assembled unit, not by the casting alone. The casting has to provide a machined, flat, porosity-free gasket land and a groove at the right depth; the gasket, fasteners and cable entries complete the seal.

The cost is in the coating and the masking, not in the casting: zinc arc spray or nickel paint, plus masking of every mating surface that must stay conductive. A powder-coated part with no conductive path is not a shield.

In production, 8–15 mm is the normal range for this class of housing, with 1.5–2.5 mm roots. Taller fins are possible but the tip thickness, draft and die wear decide the cost. The installed orientation matters as much as the geometry.

Aluminum for the housing, because weight and thermal mass both matter and the part is large. Zinc is used for small shielded fittings where thin walls and plating quality matter more than weight.

Dimensional report on the machined features, X-ray or sectioning on the gasket land for the first article, coating thickness and adhesion per lot, and leak testing on the assembled unit where your customer specifies it. The environmental tests themselves are run on the assembled product.

Related pages

Where this page connects.

Product, process and material pages that carry the same decisions.

Send the drawing. Get the engineering questions first.

Include the material, annual quantity, finishing requirement, target market and delivery date. The review can start from STEP, IGS, DWG, DXF, PDF or ZIP files.

Start an RFQ
Upload drawing